3Wood Stove Insert with Stainless Liner

A wood stove insert installed in an existing masonry fireplace, vented through a stainless steel liner in the original flue.

WOOD STOVE INSERT WITH STAINLESS LINER Side cross-section of an insert installed in an existing masonry fireplace and chimney Chimney cap Liner top plate Crown Damper block-off platesealed at the damper area Surround panel Wood stove insert Hearth extension* Existing masonry chimney Stainless steel flue liner*sized to the appliance Liner connects to insert flue collar Existing masonry fireplace * Liner sizing and listing, liner insulation, hearth extension size, and clearances vary by appliance and code. Verify with NFPA 211 / IRC R1001–R1003 / Oregon Residential Specialty Code and the manufacturer's installation manual. Simplified educational illustration — not to scale and not an installation guide.
Tap or click the diagram to open it full size.

Parts glossary

Chimney cap
Close-up drawing: Chimney cap
Cap over the liner that keeps out rain and debris; typically attached to the top plate.
Liner top plate
Close-up drawing: Liner top plate
Plate that seals the top of the flue around the liner and supports it; the cap attaches to it.
Crown
Close-up drawing: Crown
Concrete or mortar slab on top of the chimney masonry that sheds water.
Existing masonry chimney
Close-up drawing: Existing masonry chimney
The original brick chimney that now houses the liner.
Stainless steel flue liner*
Close-up drawing: Stainless steel flue liner
Listed stainless liner (flexible or rigid) running from the insert to the top of the chimney, sized to the appliance.
Damper block-off plate
Close-up drawing: Damper block-off plate
Sheet-metal plate sealed at the damper area around the liner; keeps room air from escaping up the old flue and keeps cold air and debris out.
Liner connection to insert flue collar
Close-up drawing: Liner connection to insert flue collar
Where the liner attaches to the insert’s outlet using the liner’s listed connector.
Surround panel
Close-up drawing: Surround panel
Metal panel around the insert that covers the gap between the insert and the fireplace opening.
Wood stove insert
Close-up drawing: Wood stove insert
Wood-burning heater designed to sit inside an existing fireplace firebox.
Existing masonry fireplace
Close-up drawing: Existing masonry fireplace
The original firebox and masonry that now hold the insert.
Hearth extension*
Close-up drawing: Hearth extension
Noncombustible floor area in front of the insert that protects the floor from embers.

Verify with code / manual *

Verify with NFPA 211 / IRC R1001–R1003 / Oregon Residential Specialty Code and the manufacturer’s installation manual and listing.