5Vented Gas Logs in a Masonry Fireplace

A vented gas log set installed in an existing wood-burning masonry fireplace, venting up the original flue.

VENTED GAS LOGS IN A MASONRY FIREPLACE Side cross-section of a vented gas log set installed in an existing wood-burning fireplace VENTED VS. VENT-FREE LOGS* Vented logs are decorative; the damper stays open so exhaust goes up the flue. Vent-free logs are a separate listed product with their own rules and restrictions. Chimney cap Crown Smoke chamber Gas log set (ceramic logs) Gas key valvefront corner, often a brass key Pilot / ignition (if equipped) Hearth extension* Gas supply line*up through floor, front corner Flue Flue liner (clay tile) Damper + damper clamp*clamp holds the damper open Embers / mediasand, vermiculite, or glowing embers Grate Burner pan Ash dump (at back wall) * Damper clamp requirement, gas line sizing, clearances, hearth extension, and vented vs. vent-free log use vary by code and manufacturer. Verify with NFPA 54 / NFPA 211 / Oregon Residential Specialty Code and the manufacturer's installation manual. Simplified educational illustration — not to scale and not an installation guide.
Tap or click the diagram to open it full size.

Parts glossary

Chimney cap
Metal cover over the flue that keeps out rain and debris.
Crown
Concrete or mortar slab on top of the chimney masonry that sheds water.
Flue
The open passage that carries exhaust up and out.
Flue liner (clay tile)
Clay tile sections lining the flue that protect the masonry.
Smoke chamber
The tapered space above the damper that funnels exhaust into the flue.
Damper + damper clamp*
The damper must stay open while vented logs operate; a damper clamp holds it open so it cannot be closed by mistake.
Gas log set (ceramic logs)
Ceramic logs arranged on the grate exactly as the manual shows, because placement affects the flame and sooting.
Grate
Steel rack that holds the logs above the burner pan.
Burner pan
Pan that holds the burner, covered with media so gas spreads evenly across it.
Embers / media
Sand, vermiculite, or glowing-ember material on the burner pan and around the logs, used as the manual specifies.
Pilot / ignition (if equipped)
Standing pilot or electronic ignition with a flame-sensing safety device; some log sets are match-lit and have no pilot.
Gas key valve
Manual valve at a front corner of the firebox, often brass, turned on and off with a removable key.
Gas supply line*
Gas piping that comes up through the firebox floor at a front corner, in front of the ash dump, and feeds the key valve.
Ash dump (at back wall)
Existing ash dump in the firebox floor near the back wall.
Hearth extension*
Noncombustible floor area in front of the fireplace opening.

Verify with code / manual *

Verify with NFPA 54 / NFPA 211 / Oregon Residential Specialty Code and the manufacturer’s installation manual and listing.