4Gas Insert in a Masonry Chimney

A direct-vent (sealed combustion) gas insert in an existing masonry fireplace, vented up the chimney flue with a co-linear liner system.

GAS INSERT IN A MASONRY CHIMNEY Side cross-section of a direct-vent gas insert installed in an existing masonry fireplace, vented up the chimney flue CO-LINEAR VENTING One liner carries exhaust up; a second liner brings outside combustion air down to the sealed insert. Some systems use a single co-axial liner instead.* Co-linear termination cap* Liner top plate Crown Exhaust liner*flexible aluminum Surround panel Glass front (sealed) Logs / media Pilot / ignition Burner Hearth extension* Gas supply line*up through the floor, one side Or: through a fireplace side wall near the bottom Existing masonry chimney Combustion-air intake liner*flexible aluminum Damper area*damper removed or locked open per manual Liner connections toinsert vent collars Direct-vent gas insert Gas shutoff valve Ash dump (at back wall) Existing masonry fireplace Exhaust (up the exhaust liner) Combustion air (down the intake liner) * Liner type, size and listing, termination cap, damper handling, gas line sizing, hearth extension, and clearances vary by manufacturer and code. Verify with NFPA 54 / IRC (fuel gas) / Oregon Residential Specialty Code and the manufacturer's installation manual. Simplified educational illustration — not to scale and not an installation guide.
Tap or click the diagram to open it full size.

Parts glossary

Co-linear termination cap*
Close-up drawing: Co-linear termination cap
Listed cap at the top of the chimney that terminates both liners: exhaust out, combustion air in.
Liner top plate
Close-up drawing: Liner top plate
Plate that seals the top of the flue around the liners and supports them.
Crown
Close-up drawing: Crown
Concrete or mortar slab on top of the chimney masonry that sheds water.
Existing masonry chimney
Close-up drawing: Existing masonry chimney
The original brick chimney that now houses the vent liners.
Exhaust liner* (flexible aluminum)
Close-up drawing: Exhaust liner (flexible aluminum)
Liner that carries combustion exhaust from the insert up and out of the chimney.
Combustion-air intake liner* (flexible aluminum)
Close-up drawing: Combustion-air intake liner (flexible aluminum)
Liner that brings outside air down to the sealed firebox for combustion. Some systems use a single co-axial liner (pipe within a pipe) instead of two liners.
Damper area*
Close-up drawing: Damper area
Where the old damper was; removed or locked fully open as the insert manual requires so it cannot close on the liners.
Liner connections to insert vent collars
Close-up drawing: Liner connections to insert vent collars
Where the exhaust and air-intake liners attach to the insert’s two vent collars.
Direct-vent gas insert
Close-up drawing: Direct-vent gas insert
Sealed-combustion gas heater that takes all combustion air from outside and vents all exhaust outside.
Glass front (sealed)
Close-up drawing: Glass front (sealed)
Glass panel that seals the firebox from the room; it is part of the sealed combustion system.
Logs / media
Close-up drawing: Logs / media
Ceramic logs, glass, or stones; place them exactly as the manual shows, because placement affects the flame and sooting.
Pilot / ignition
Close-up drawing: Pilot / ignition
Standing pilot or electronic ignition that lights the burner, with a flame-sensing safety device.
Burner
Close-up drawing: Burner
Where gas mixes with air and burns.
Gas shutoff valve
Close-up drawing: Gas shutoff valve
Manual valve that shuts off gas to the appliance; it must stay accessible.
Gas supply line*
Close-up drawing: Gas supply line
Gas piping that typically comes up through the firebox floor in front of the ash dump (toward one side) or through a fireplace side wall near the bottom.
Surround panel
Close-up drawing: Surround panel
Panel around the insert that covers the gap to the fireplace opening.
Ash dump (at back wall)
Close-up drawing: Ash dump (at back wall)
Existing ash dump in the firebox floor near the back wall, left in place under the insert.
Existing masonry fireplace
Close-up drawing: Existing masonry fireplace
The original firebox and masonry that now hold the insert.
Hearth extension*
Close-up drawing: Hearth extension
Noncombustible floor area in front of the insert, as the insert’s listing requires.

Verify with code / manual *